RB iconIP iconMPE iconRBAS iconRouse icon

CAT SR4B-GD

부가세 제외가격

Favorite즐겨찾기
share공유
Save search검색 저장
출력

INFO

제품군
디젤 발전기
제작사/모델
CAT SR4B-GD
제작년도
2012
컨디션
Used
장비위치
Langley, British Columbia
국가
캐나다
마스쿠스 ID
5408F2EF

가격

화폐 선택

세부정보

재고번호
138143
기타 정보
1475 kW, 1843 kVA, 50 Hz Natural Gas Generator SR4B-GD w/ Engine 3516C Title: 1475 kW, 1843 kVA, 50 Hz Natural Gas Generator SR4B-GD w/ Engine 3516C SKU: 138143 Model: SR4B-GD Year: 2012 Condition: Used S/N: G5Z01287 GeneralHorsepower:1978hp Fuel Type:Natural Gas Hours:27582.4 Rating:Continuous ElectricalkVA:1843kVA Voltage:400volts Phase:3-phase Made In: UNITED STATES Dimensions: 122.00 (H) x 118.00 (W) x 480.00 (L) inches Overhaul done at 26210 hours Ran for 1300 hours after overhaul Currently set for 50hz but can bump frequency up to 60hz Engine: - Caterpillar 3516C - Advertised power: 1622 kW // 2175 hp - Full load speed: 1500 RPM - Comp. ratio: 11.3:1 Overhaul Job Description: - Engine Major Overhaul - The cylinder block of generator set NO.5 is installed - Replaced main and rod bearings, piston rings, thermostat, and other wear parts - Replaced all seals on the unit; -Replaced 16 pistons and 4 cylinder liners - Repaired the cylinder head, parts not replaced; -Replaced two water pumps with REMAN parts - Repaired the oil pump - Cleaned and pressured test the oil cooler - Visually inspected the turbocharger. Left turbocharge used again, right turbocharge to be repaired - The coupling has been damaged and continues to be used without replacement Generator Maintenance: - It used the generator of the NO 5 genset set after maintenance - Replaced front and rear bearings and grease seals - Replaced front and rear bearing outer rings - Performed laser cladding on the rear ends of the main shaft - Performed VPI (Vacuum Pressure Impregnation) insulation treatment and drying - Conducted rotor dynamic balance test - Conducted overall performance testing Shaft Alignment Check: - Engine and Generator Shaft Alignment Radiator Check: - The water tank of genset 5 was installed into genset 6 - Radiator Disassembly, Reassembly, and Cleaning Generator Set D&A: - Continued to use the container of generator Set 6 - Generator Set Entry and Exit from the Container Overall Performance Testing: - Tested according to Caterpillar test standard 349-6498 (see attachment for details), with a maximum load reaching 60%. As all cylinder heads installed are manually refurbished on site, please note that the long-term load must not exceed 60%

Lenmark Industries Ltd

27576 51a Ave V4W 4A9 Langley British Columbia 캐나다
1
Mascus 이용 기간(년)
report ad의심스러운 광고 보고